LTC3780 DC 5-32V to 1V-30V 10A Auto Buck Boost Module Auto Step-up Step-Down

T243-L2D13

Baru

5 item

Rp. 168.000


LTC3780 DC 5-32V to 1V-30V 10A Auto Buck Boost Module Auto Step-up Step-Down

Electrical Parameters (Non-Isolated Lift Module):
1. Input Voltage: DC5-32v, It Is Recommended To Use Voltage Above 10v
2. Output Voltage: DC1v-30v Continuous Adjustable;
3. Output Current: 10a (Max) Long-Term 7a or Less;
4. Output Power: Long-Term 80w, Peak 130w, More Than 80w Please Strengthen Heat Dissipation;
5. Output Ripple: 50mv (12v To 12v, 5a Measured);
6. Input Back-Join Protection: None, If Necessary, Please Series Schottki Diodes At The Input;
7. Output Anti-Reverse Irrigation: None, If Used For Battery Charging Or The Load Is Self-Contained Inductive Load, Please Series Schottki Diodes At The Output End;
8. Size: 77.6 x 46.5 x 15mm
9. Short-Circuit Protection: Yes;
10. Weighs About 45 Grams;

Debugging Method:
1. Battery Undervoltage Protection Adjustment Method: (Take 12v Lead-Acid Battery Setting 10v Undervoltage Protection, Shut-Off Output As An Example)
The Input-Regulated Power Supply Is Adjusted To 10v And The Undervoltage Protection Potential (Clockwise Increased, Counterclockwise Reduced) Is Adjusted Until The Fault Indicator (Red Light) Is On, i.e. The Setting Is Successful;
Note: If It Is Not Battery Powered Can Not Do The Setting;
2. Output Voltage Adjustment Method: Input Power Supply (Voltage Is Higher Than Undervoltage Protection Value), Red Light Is Not On, Blue Light Is On, Output Is Connected To The Meter, Adjust The Output Voltage Potential (Clockwise Increase, Counterclockwise Decrease) Until The Required Voltage;
Note: Normal Red Light Does Not Light, Blue Light On, On The Contrary, There Is a Fault, Input Undervoltage Protection, Output Overcurrent Protection, Output Short-Circuit Protection, Please Troubleshoot And Power Up Again.
3. Output Current Adjustment Method: (Charge 12v Input Charge 12v Lead-Acid Battery, Charging Current 5a As An Example)
Input 12v Power Supply, Universal Meter Current, Output And Join Universal Meter (Red Watch Pen Connection Output Positive, Black Table Pen Negative, Direct Short Output). It Is Recommended To Use More Than 15a Current File To Prevent Burning Insurance, Adjust The Constant Current Potential (Clockwise Increase, Counterclockwise Decrease) Until The Current Display Required Value 5a, Remove The Universal Meter, Connect The Battery Can Be Charged Normally. If The Output Current Is Adjusted With a Current Meter, The Correct Wiring Commissioning Is Made With Reference To The Corresponding Wiring Line Of The Ammeter.

Note: For Constant Pressure Equipment, Only The Maximum Output Current Needs To Be Set.