PSU Dual Output 5V 2.2A + 24V 1A

B317-L2D10

Baru

67 item

Rp. 100.000


PSU Dual Output 5V 2.2A + 24V 1A

model

D-30B

CH1

CH2

DC output voltage

5V

24V

Output voltage tolerance (Note 2)

± 2%

± 3%, - 5%

Rated output current

2.2A

1A

Output Current Range

1-2.2A

0.1-1A

Ripple and noise (Note 3)

50mVp-p

100mVp-p

Line stability (Note 4)

± 0.5%

± 1%

Load Regulation (Note 5)

± 0.5%

± 4%

DC output power

35W

effectiveness

74%

DC voltage adjustable range

CH1; + 10, -5%

Input voltage range

85 ~ 132VAC / 170 ~ 264VAC selected by a switch 47 ~ 63Hz; 240 ~ 370VDC

Input Current

0.8A / 115V 0.45A / 230V

Inrush current

Cold start current 18A / 115V 36A / 230V

Leakage current

<0.5mA / 240VAC

Overload

105% ~ 150% Type: cut output reset: automatic recovery

Overvoltage protection

..........

Temperature Coefficient

± 0.03% / ℃ (0-50 ℃) ON + 5V

Start, rise, holding time

200ms, 100ms, 30ms

Shock resistance

10 ~ 500Hz, 2G 10min, / 1 cycle, duration 60 minutes each axis

Pressure resistance

Input and output: 1.5KvAC Input and enclosure: 1.5KvAC Output and enclosure: 0.5KvAC

Isolation resistance

Input and output: Input and enclosure, Output and enclosure: 500VDC / 100MΩ

Temperature, humidity

-10 ℃ ~ + 60 ℃ (refer to output characteristic diagram), 20% ~ 90% RH

Dimensions

129 × 98 × 38mm

weight

0.4Kgs

safety standard

Meet UL1012 requirements (does not apply mark)

EMC standard

Meet FCC Part 15J condition grade B

Note: 
1, the above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH, humidity. 
2, Tolerance: includes set up tolerance, line regulation, load regulation (Note 5). 
3, the ripple test: 20MHz with "A12" twisted pair, interrupted with 0.1uF-47uF capacitor short circuit. 
4, the line voltage stability test: full load always the lowest voltage to the highest voltage. 
5, load stability test: load from 0% to 100%. 
6, each up to the maximum output current, but the total load must not exceed the maximum output power.